Jump to content

Leaderboard

Popular Content

Showing content with the highest reputation on 06/23/19 in all areas

  1. I've been working on this for a while. My wife's due to give birth any day now and this is what I'm going to give her after the baby is born. This is my first attempt at restoring a dial. HSL was kind enough to send me a spare one to practice on. Which I did, and it ended up being the final one I used. What was also interesting, I attempted Mark's laser printed logo method.Which worked surprisingly well. The edges of the print aren't quite as sharp as the original. But you would have to have a very expert eye to tell the difference. I think with a very high DPI laser printer you could get this more or less perfect.
    4 points
  2. ETA 7750 Service Walkthrough The 7750 was first available in 1974, having been one of the first movements to be designed with the aid of a computer. It's hard to believe that the 7750 is still the industry standard movement for chronographs considering it's history. It was developed over 40 years ago by Valjoux, who was then a legendary movement maker that was part of the giant ASUAG conglomerate. But by the end of 1975 production was stopped due to the onslaught of the Quartz Era, and the 7750, along with many other mechanical calibers, was abandoned. Industry demand for this movement was so low that the stock produced in that 1 year manufacturing lasted until 1982! Such was the devastation of cheap Japanese produced quartz watches to Swiss manufactures. History may have forgotten the 7750 except for the local management at Zenith who ignored the orders by Valjoux to destroy the dies and equipment used to manufacture the 7750, instead hiding the equipment away from corporate eyes. You can find many more fascinating facts about this caliber online, and it's well worth the read. ................................................... This walkthrough will be very detailed, and I hope this will give people the courage to tackle this movement. I've serviced quite a few calibers, and this is one of the most beautiful, with a very logical layout. ETA7750 Tech.PDF If you have built your skills with basic movements, and become proficient in servicing them, I would highly recommend this movement to be your first chronograph to tackle. Lets begin. DEMAGNETIZE THE MOVEMENT BEFORE DISASSEMBLY. Remove the Day Indicator and store it in a safe place where it won't be damaged. Unscrew (0.8 Driver) the Jumper Maintaining Plate and remove it. Do the same for the Date Indicator Maintaining Plate Carefully remove the Jumpers Spring, holding it with a piece of pegwood so it doesn't ping away. Next remove the jumpers for the day and date. The jumpers differ from one another, so here is a reference photo so you can see the difference. Remove the Date Indicator and place it in a safe place where it won't be damaged. The last piece to remove on the Date Platform is the Double Corrector Now unscrew (1.4 Driver) the Date Platform and gentle pry it from the movement. Be careful when removing this plate, as there is a fine spring pressed into the plate that can be easily damaged. Here is a reference photo of the screws that hold the Date Platform. Remove the Hour Hammer Spring, once again using the pegwood to hold the spring while removing the tension. Here is a reference photo of the correct orientation of the spring. Remove the Hour Counter Lock. Remove the Hour Hammer Operating Lever. Next is the Hour Hammer, be careful when removing this item so as not to damage the Hour-Counting Wheel. Now remove the Hour-Counting Wheel. Remove the Date Indicator Driving Wheel Remove the Day Star Driving Wheel Then remove the Intermediate Calendar Driving Wheel Remove the Hour Wheel Then the Minute Wheel Remove the Cannon Pinion, which does not require a puller. The last component to be removed on this side of the Main Plate is the Driver Cannon Pinion. To lift the Driver Cannon Pinion I used what Mark used, a set of hand lifter from Horotec (MSA05.007); but you can also use a Presto Tool (30636-1) which will also work well. The dial side of the movement is now complete disassembled. Flip the movement over and unscrew (1.5 Driver) the Oscillating Weight. To remove the Hammer Spring lift it up gently over the automatic work and move it inwards. This will move the tail of the spring in a clockwise motion to the opening in the slots, which will free the spring. Slide out the Clutch Spring. Here is a reference photo of this spring, and it's orientation. Remove the screws (1.4 Driver) for the Automatic Device Bridge, and gently pry it loose. Here is a reference photo of these screws for the bridge. Once the Automatic Bridge has been removed, the two wheels for the automatic work are able to be removed. Below is a reference photo of how the sit inside the bridge. We now begin to disassemble the chronograph section of this movement. Begin with removing the Hammer, 2 Functions. Next remove the Clutch 60s, 2 Functions. Then remove the Minute-counting Wheel, 30min. Remove the Chronograph Wheel 60s, 30min. Gently lift out the Oscillating Pinion, 60s. Here is a reference photo of the orientation of this pinion. Unscrew (1.4 Driver) the Chronograph Bridge and gently pry it off the Train Wheel Bridge. Remove the Ratchet Driving Wheel. Remove the Chronograph Wheel Fiction. Unscrew (1.4 Driver) the Operating Lever, 2 Functions. Unscrew (1.4 Driver) the Lock, 2 Functions. Next remove the Minute-counter Driving Wheel, 30min. Slide out the Operating Lever Spring, 2 Functions. This spring can be fitting in both directions; but only 1 way is correct. Here is a reference photo of it's correct orientation. Remove the Switch. Here I digress from the order the SwissLab document illustrates the order of removal. They show to remove the Chronograph Cam before removing the Hammer Cam Jumper. This in my opinion is not the best way, as all the force from the jumper is pressing on the cam whilst your trying to remove it, and could lead to damage. Instead I move the Chronograph Cam until it reaches the notch as shown in the photo below. Then lift the Hammer Cam Jumper up to the top of the Chronograph Cam, which will release it's tension. Then, just as you removed the previous hammer, rotate the jumper to the opening in the slots, which will free the spring. Now you can unscrew (1.4 Driver) and remove the Chronograph Cam safely without tension on it. RELEASE THE MAINSPRING TENSION Once the tension has been released, unscrew (1.4 Driver) and remove the Balance Cock. Then unscrew (1.4 Driver) the Pallet Bridge and remove the bridge and Pallets. Unscrew (1.2 Driver) and remove the Ratchet Wheel. Then remove the Crown Wheel. Unscrew (1.4 Driver) the Train Wheel Bridge and gently pry it off the Main Plate. Note that one of the screws is under the Operating Lever. This needs to be moved out of the way to access this screw. The last level of this movement contains the train. Here is a reference photo of the wheel locations. Remove the Stop Lever. Remove the Great Wheel. Here is a reference photo of the underneath of this wheel. Remove the Third Wheel. Here is a reference photo of the underneath of this wheel. Remove the Second Wheel. Here is a reference photo of the underneath of this wheel. Note this has the long lower pivot. Remove the Escape Wheel. Here is a reference photo of the underneath of this wheel. Then remove the Barrel. This completes the removal of the train. Flip the movement over so we can complete the disassembly by removing the keyless work. Firstly, release the tension from the Setting Lever Jumper. Then unscrew (1.2 Driver) and remove the Setting Lever Jumper. These are unique screws with pointed ends, and below is a reference photo of them. This will also remove the Intermediate Setting Wheel. Next remove the Setting Wheel Then remove the Yoke. Remove the Setting Lever. Remove the Rocking Bar. Now pull out the Stem. Once the Stem is removed the Winding and Sliding Pinion should fall out of the movement onto your work mat. Disassembly of the 7750 is now complete If you've come this far, congratulation on completing the disassembly. Make sure you pegwood all the jewels and reinstall the Balance back onto the movement for cleaning. Assembly of the movement will be posted as soon as I complete the write-up.
    1 point
  3. Hello all,I'm Paul and I am a new member of the forum and even newer to attempting watch repairs.I live in Durham UK and have always appreciated a nice looking watch. Please be patient if I ask too many/stupid questions
    1 point
  4. Agreed. I played around for a couple of hours, then left it till the next day and made my little tool which did the trick.
    1 point
  5. You might also be interested in previous postings on this forum e.g. https://www.watchrepairtalk.com/topic/11157-seiko-7s26-shock-springs
    1 point
  6. Seiko only call the shock absorbing spring . Number 0014577 .
    1 point
  7. Only seen them on newer 7 series movements and some newer Seiko movement. They are a pain in the .... to put back.
    1 point
  8. Yesterday's eBay deliveries. A nice pin pallet that's the cleanest I've ever seen, came with the pallet fork loose, refitted and ticking away, will get a service and back onto eBay at some point. Then an 'interesting' Seiko franken. Lovely clean 7019A movement, (which was the reason for the purchase) bonus of new strap, practise dial to strip and make a dial from and hands.
    1 point
  9. if you can buy (locate) a new mvt., it would a good project. vin
    1 point
  10. Glad you found it useful. I was impressed at how quiet it was as well. For such an old machine, I sort of expected wear in bearings or something to perhaps create some imbalance and vibration, but no, steady as anything. Certainly downward force on these older machines, but mostly nowadays they are automatic and bi-directional and as far as I know the “rotor” part does not exist anymore, so there is no imparting of a flow direction when it rotates. I think for the average hobbyist, just using a machine, even of this vintage, is going to make a such a difference to cleanliness, that it won’t really matter. still can’t wait to hear about you starting on your machine. I wish you well with it. G.
    1 point
  11. looks like its coming along nicely, try pressing a little softer or even try going down to a 3 micron paper. best of luck
    1 point
  12. Thanks for the positive feedback guys. Editing the photos and writing up the walkthrough is far more difficult then the service on this movement. :p I had to rebuild the software from scratch on a friends PC today, so that put me a little behind in this service, but I'm back into it now. Parts are in the cleaning machine as I type this up, so the assembly and write-up shouldn't be far off, Lord willing.
    1 point
  13. Had a bit of practice fitting a shock spring which was fun, and ended up making a little tool to fit it back into the movement. Anyone know what the spring is called, movement is a Seiko 7S26. Many thanks from Jon
    0 points
×
×
  • Create New...